Investigation of Chloride Ion Penetration Resistance of Silica Fume Mix Concrete

dc.contributor.authorKrishnathilaka, R.K.S.
dc.contributor.authorPerera, L.A.
dc.contributor.authorAmarakoon, A.M.M.W.
dc.contributor.authorUdamulla, K.M.L.A.
dc.contributor.authorKarunananda, P.A.K.
dc.date.accessioned2015-12-01T08:39:17Z
dc.date.available2015-12-01T08:39:17Z
dc.date.issued2015-12-01T08:39:17Z
dc.date.published2015
dc.description.abstractSri Lanka, being an island with well developed coastal areas, has a large number of reinforced concrete (RC) structures in the coastal zone. Chloride attack on such concrete structures has become a significant issue in the construction sector and it has become necessary to curtail the adverse effects of chloride ions which lead to corrosion of reinforcing steel and subsequent reduction in the strength, serviceability, and aesthetics of structures and finally the failure of structures. The level of chloride ion penetration is related to concrete permeability and with increasing permeability, an increase of chloride ion penetration occurs. Studies have indicated that the addition of materials such as fly ash, ground granulated blast furnace slag and silica fume in certain proportions in the mix reduces the penetrability of concrete. Hence, a possibility exists for the retardation of chloride ion penetration under such conditions. In this study, the chloride ion penetration resistance of silica fume mix concrete was examined. The physical properties of silica fume (fineness, specific gravity and water absorption) were determined in the study. Concrete mix of Grade 25 was tested according to the BS Mix Design Method. Specimens with Ordinary Portland Cement (OPC) concrete and specimens with OPC replaced by silica fume at the levels of 5%, 10% and 15% by weight of cement were tested. Compressive strength tests (according to BS 1881-116-1983) were carried out on concrete cubes of size 150 mm x 150 mm x 150 mm. Workability was measured by the slump test, compacting factor test and VB test. Chloride Ion Penetration test was carried out according to the procedure given in ASTM C-1202. The results indicated that the workability reduces with the increase of silica fume for Grade 25 concrete. The compressive strength of silica fume mix concrete decreased with the increase of silica fume content in the concrete. However, the results of Chloride Ion Penetration test revealed that the addition of silica fume reduced the chloride ion penetration indicating a reduced level of chlorine attack in concrete.en_US
dc.identifier.citationKrishnathilaka, R.K.S., Perera, L.A., Amarakoon, A.M.M.W., Udamulla, K.M.L.A., & Karunananda, P.A.K. (2015). Investigation of Chloride Ion Penetration Resistance of Silica Fume Mix Concrete. Proceedings of the 71st Annual Sessions of Sri Lanka Association for the Advancement of Science (Part I), 37.
dc.identifier.issn13910248
dc.identifier.urihttp://dr.lib.sjp.ac.lk/handle/123456789/2027
dc.language.isoenen_US
dc.publisherSri Lanka Association for the Advancement of Science, Colombo 07
dc.subjectChloride penetrationen_US
dc.subjectsilica fumeen_US
dc.subjectconcreteen_US
dc.titleInvestigation of Chloride Ion Penetration Resistance of Silica Fume Mix Concreteen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Investigation of chloride ion penetration resistance of silica fume mix concrete.pdf
Size:
132.33 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.8 KB
Format:
Item-specific license agreed upon to submission
Description: